INTEGRAL/SPI ground calibration (2006)
Attié, D., Cordier, B., Gros, M., Laurent, Ph., Schanne, S., Tauzin, G., ...
Three calibration campaigns of the spectrometer SPI have been performed before launch in order to determine the instrument characteristics, such as the effective detection area, the spectral...
Search for cyclotron lines in INTEGRAL/SPI spectra of Vela X-1 (2006)
Attié, D., Schanne, S., Sizun, P., Kreykenbhom, I., Staubert, R., Kretschmar, P., ...
The INTEGRAL spectrometer SPI: performance of point-source data analysis (2005)
Dubath, P., Knödlseder, J., Skinner, G. K., Connell, P., Kreykenbohm, I., Strong, A., ...
The STAFF-DWP wave instrument on the DSP equatorial spacecraft: description and first results (2005)
Cornilleau-Wehrlin, N., Alleyne, H. St., Yearby, K. H., Meyer, A., Santolik, O., ...
The STAFF-DWP wave instrument on board the equatorial spacecraft (TC1) of the Double Star Project consists of a combination of 2 instruments which are a heritage of the Cluster mission: the...
The STAFF-DWP wave instrument on the DSP equatorial spacecraft: description and first results (2005)
Cornilleau-Wehrlin, N., Alleyne, H. St., Yearby, K. H., Meyer, A., Santolik, O., ...
The STAFF-DWP wave instrument on board the equatorial spacecraft (TC1) of the Double Star Project consists of a combination of 2 instruments which are a heritage of the Cluster mission: the...
The INTEGRAL/SPI response and the Crab observations (2004)
Sizun, P., Shrader, C. R., Attié, D., Dubath, P., Schanne, S., Cordier, B., ...
The Crab region was observed several times by INTEGRAL for calibration purposes. This paper aims at underlining the systematic interactions between (i) observations of this reference source, (ii)...
The INTEGRAL/SPI response and the Crab observations (2004)
Sizun, P., Shrader, C. R., Attié, D., Dubath, P., Schanne, S., Cordier, B., ...
The Crab region was observed several times by INTEGRAL for calibration purposes. This paper aims at underlining the systematic interactions between (i) observations of this reference source, (ii)...
The INTEGRAL/SPI response and the Crab observations (2004)
Sizun, Patrick, Shrader, C. R., Attié, D., Dubath, P., Schanne, S., Cordier, B., ...
The Crab region was observed several times by INTEGRAL for calibration purposes. This paper aims at underlining the systematic interactions between (i) observations of this reference source, (ii)...
Search for 44 Ti gamma-ray line emission from GRO J0852-4642 with INTEGRAL/SPI (2004)
Kienlin, A. Von, Attié, D., Schanne, S., Cordier, B., Diehl, R., Iyudin, A. F., ...
INTEGRAL broadband spectroscopy of Vela X-1 (2004)
Kretschmar, P., Staubert, R., Kreykenbohm, I., Chernyakova, M., Kienlin, A. V., Larsson, S., ...
Performance of SPI point-source data analaysis (2004)
Dubath, Pierre, Kreykenbohm, I., Knödlseder, J., Connell, P., Skinner, G. K., Strong, A., ...
The INTEGRAL/SPI response and the Crab observations (2004)
Sizun, Patrick, Shrader, C. R., Attié, D., Dubath, P., Schanne, S., Cordier, B., ...
The Crab region was observed several times by INTEGRAL for calibration purposes. This paper aims at underlining the systematic interactions between (i) observations of this reference source, (ii)...
Calibration of the Spectrometer aboard the INTEGRAL satellite (2003)
Schanne, Stéphane, Cordier, B., Gros, M., Attié, D., Ballmoos, P. V., Bouchet, L., ...
SPI, the Spectrometer on board the ESA INTEGRAL satellite, to be launched in October 2002, will study the gamma-ray sky in the 20 keV to 8 MeV energy band with a spectral resolution of 2 keV for...
INTEGRAL/SPI ground calibration (2003)
Attié, D., Cordier, B., Gros, M., Laurent, Ph., Schanne, S., Tauzin, G., ...
Three calibration campaigns of the spectrometer SPI have been performed before launch in order to determine the instrument characteristics, such as the effective detection area, the spectral...
INTEGRAL/SPI ground calibration (2003)
Attié, D., Cordier, B., Gros, M., Laurent, Ph., Schanne, S., Tauzin, G., ...
Three calibration campaigns of the spectrometer SPI have been performed before launch in order to determine the instrument characteristics, such as the effective detection area, the spectral...
INTEGRAL/SPI ground calibration (2003)
Attié, D., Cordier, B., Gros, M., Laurent, Ph., Schanne, S., Tauzin, G., ...
Three calibration campaigns of the spectrometer SPI have been performed before launch in order to determine the instrument characteristics, such as the effective detection area, the spectral...
INTEGRAL/SPI ground calibration (2003)
Attié, D., Cordier, B., Gros, M., Laurent, Ph., Schanne, S., Tauzin, G., ...
Monte Carlo simulations and generation of the SPI response (2003)
Sturner, S. J., Shrader, C. R., Weidenspointner, G., Teegarden, B. J., Attié, D., Cordier, B., ...