ABSTRACTS (2009)

Abdelwahab, A., Gardner, M., Parkash, R., Basta, M., Sapp, J., Veltmann, C., ...

Introduction: Scar-related ventricular tachycardia (VT) is often unmappable. Data regarding the outcomes of ablation for mappable vs unmappable VT are lacking. Methods: Catheter ablation of...

Comparison of generic health survey SF-36 and arrhythmia related symptom severity check list in relation to post-therapy AF recurrence (2003)

Berkowitsch, A., Neumann, T., Kurzidim, K., Reiner, C., Kuniss, M., Siemon, G., ...

Aim The effect of applied therapy on quality of life (QoL) in patients with atrial fibrillation (AF) was investigated in recent studies. However, no information on clinical relevance of QoL assessing...

Automatic capture verification in ICD lead systems using intracardiac ventricular evoked response and reduced coupling capacitance (2003)

Sperzel, J., Pitschner, H. F., Schwarz, T., König, A., Zhu, Q., Neuzner, J.

Aim Intracardiac ventricular evoked-response (ER) signals detected by implanted cardioverter defibrillator (ICD) lead systems were investigated for automatic capture verification (AC). Method ER...

Dual-coil vs single-coil active pectoral implantable defibrillator lead systems: defibrillation energy requirements and probability of defibrillation success at multiples of the defibrillation energy requirements (2001)

Schulte, B., Sperzel, J., Carlsson, J., Schwarz, T., Ehrlich, W., Pitschner, H. F., ...

Aims The aim of the study was to compare the defibrillation energy requirements and the probability of successful defibrillation at multiples of the minimum defibrillation energy requirements in...

Detection of ventricular fibrillation in implantable defibrillators with automatic gain control amplifiers: Effects of programming sensitivity (2000)

Schulte, B., Sperzel, J., Schwarz, T., Pitschner, H.F., Strupp, G., Neuzner, J.

Aims In newer implantable cardioverter–defibrillators with automatic gain control amplifiers the maximum possible sensitivity is programmed with the aim of securing optimal detection of ventricular...

Bipolar atrial sensing thresholds in sinus rhythm and atrial tachyarrhythmias: A comparative analysis in patients with DDDR pacemakers (1999)

Neuzner, J., Sperzel, J., Pitschner, H. F., Schwarz, T., Ehrlich, W., Schulte, B., ...

Automatic mode switching (AMS) function in dual chamber pacemakers depends on adequate detection of atrial tachyarrhythmias. There are few data on showing how intra-operative atrial signal...

123I-metaiodobenzylguanidine scintigraphy in the detection of irregular regional sympathetic innervation in long QT syndrome (1993)

MÜLLER, K. D., JAKOB, H., NEUZNER, J., GREBE, S. F., SCHLEPPER, M., PITSCHNER, H. F.

Twelve patients with the long QT syndrome were studied to determine the usefulness of 123I-metaiodobenzylguanidine (MIBG) single-photon emission tomography (SPECT) at 2 h and 6 h after injection; the...