Progress in fabrication and development of Ta-Al/Al (2007)
Al Superconducting, P. Hettl, G. Angloher, M. Bruckmayer, F. V. Feilitzsch, J. Jochum, ...
A new design for a cryogenic X-ray detector has been developed and verified to be successful. Absorption of 5:89 keV X-rays in a 450 ¯m\Theta160 ¯m tantalum film was detected by measurement of...
A Textured Silicon Calorimetric Light Detector (2003)
Frank, T., Angloher, G., Bruckmayer, M., Cozzini, C., Hauff, D., ...
We apply the standard photovoltaic technique of texturing to reduce the reflectivity of silicon cryogenic calorimetric light detectors. In the case of photons with random incidence angles, absorption...
A textured silicon calorimetric light detector (2003)
Di Stefano, P., Frank, T., Angloher, G., Bruckmayer, M., Cozzini, C., Hauff, D., ...
A textured silicon calorimetric light detector (2003)
Di Stefano, P., Frank, T., Angloher, G., Bruckmayer, M., Cozzini, C., Hauff, D., ...
A textured silicon calorimetric light detector (2003)
Di Stefano, P., Frank, T., Angloher, G., Bruckmayer, M., Cozzini, C., Hauff, D., ...
A Textured Silicon Calorimetric Light Detector (2003)
Frank, T., Angloher, G., Bruckmayer, M., Cozzini, C., Hauff, D., ...
We apply the standard photovoltaic technique of texturing to reduce the reflectivity of silicon cryogenic calorimetric light detectors. In the case of photons with random incidence angles, absorption...
A textured silicon calorimetric light detector (2003)
Di Stefano, P., Frank, T., Angloher, G., Bruckmayer, M., Cozzini, C., Hauff, D., ...
A textured silicon calorimetric light detector (2003)
Di Stefano, P., Frank, T., Angloher, G., Bruckmayer, M., Cozzini, C., Hauff, D., ...
Limits on WIMP dark matter using sapphire cryogenic detectors (2002)
Anghoher, G., Bruckmayer, M., Bucci, C., Buehler, M., Cooper, S., Cozzini, C., ...
Limits on WIMP dark matter using sapphire cryogenic detectors (2002)
Anghoher, G., Bruckmayer, M., Bucci, C., Buehler, M., Cooper, S., Cozzini, C., ...
Development of 300 g scintillating calorimeters (2002)
Frank,T., Angloher,G., Bruckmayer,M., Cozzini,C., Di Stefano,P., Hauff,D., ...
The sensitivity of WIMP detection can be improved by an ability to efficiently discriminate the gamma and beta backgrounds from the nuclear recoil signals. The CRESST phase II detectors will achieve...
Limits on WIMP Dark Matter using Sapphire Cryogenic Detectors (2002)
Angloher,G., Bruckmayer,M., Bucci,C., Bühler,M., Cooper,S., Cozzini,C., ...
Data taken by CRESST with a cryogenic detector system based on 262 g sapphire crystals has been used to place limits on WIMP dark matter in the Galactic Halo. The experiment was especially sensitive...
Results of CRESST Phase I (2002)
Pröbst,F., Angloher,G., Bruckmayer,M., Bucci,C., Cooper,S., Di Stefano,P., ...
Results of the CRESST experiment at Gran Sasso using 262 g sapphire calorimeters with tungsten phase transition thermometers are presented. Calibration and analysis methods are described. Data taken...
Development of 300 g scintillating calorimeters (2002)
Frank, T., Angloher, G., Bruckmayer, M., Cozzini, C., Di Stefano, P., Hauff, D., ...
The sensitivity of WIMP detection can be improved by an ability to efficiently discriminate the gamma and beta backgrounds from the nuclear recoil signals. The CRESST phase II detectors will achieve...
Limits on WIMP Dark Matter using Sapphire Cryogenic Detectors (2002)
Angloher, G., Bruckmayer, M., Bucci, C., Bühler, M., Cooper, S., Cozzini, C., ...
Data taken by CRESST with a cryogenic detector system based on 262 g sapphire crystals has been used to place limits on WIMP dark matter in the Galactic Halo. The experiment was especially sensitive...
Results of CRESST Phase I (2002)
Pröbst, F., Angloher, G., Bruckmayer, M., Bucci, C., Cooper, S., Di Stefano, P., ...
Results of the CRESST experiment at Gran Sasso using 262 g sapphire calorimeters with tungsten phase transition thermometers are presented. Calibration and analysis methods are described. Data taken...
Results and plans of the CRESST dark matter search (2001)
Altmann, M., Angloher, G., Bruckmayer, M., Bucci, C., Cooper, S., Cozzini, C., ...
Data taken by CRESST in 2000 with a cryogenic detector system based on 262 g sapphire crystals is used to place limits on WIMP dark matter in the Galactic Halo. The detector is especially sensitive...
The CRESST Experiment: Recent Results and Prospects (2000)
Di Stefano, P., Bruckmayer, M., Bucci, C., Cooper, S., Cozzini, C., Von Feilitzsch, F., ...
The CRESST experiment seeks hypothetical WIMP particles that could account for the bulk of dark matter in the Universe. The detectors are cryogenic calorimeters in which WIMPs would scatter...
Meunier, P., Bravin, M., Bruckmayer, M., Giordano, S., Loidl, M., Meier, O., ...
We have developed a detector, consisting of a cryogenic calorimeter with a scintillating crystal as absorber, and a second calorimeter for the detection of the scintillation light, both operated at...
The CRESST Dark Matter Search (1999)
Bravin, CRESST-Collaboration: M., Bruckmayer, M., Bucci, C.
The current status of CRESST (Cryogenic Rare Event Search using Superconducting Thermometers) and new results concerning the detector development are presented. The basic technique of CRESST is to...
Imaging cryogenic detectors for astro and particle physics. (1999)
Bruckmayer, M, Oxford Univ. (GB).
Thesis (Ph.D.)
A Textured Silicon Calorimetric Light Detector
Frank,T., Angloher,G., Bruckmayer,M., Cozzini,C., Hauff,D., ...
We apply the standard photovoltaic technique of texturing to reduce the reflectivity of silicon cryogenic calorimetric light detectors. In the case of photons with random incidence angles, absorption...