W. Seidel

Details der Publikationsliste

Zeitraum

1931 - 2009

Anzahl

182

Co-Autoren

Scintillator Non-Proportionality and Gamma Quenching in CaWO4 (2009)

Lang, R. F., Angloher, G., Bauer, M., Bavykina, I., Bento, A., Brown, A., ...

We measure and explain scintillator non-proportionality and gamma quenching of CaWO4 at low energies and low temperatures. Phonons that are created following an interaction in the scintillating...

Electron and Gamma Background in CRESST Detectors (2009)

Lang, R. F., Angloher, G., Bauer, M., Bavykina, I., Bento, A., Brown, A., ...

The CRESST experiment monitors 300g CaWO_4 crystals as targets for particle interactions in an ultra low background environment. In this paper, we analyze the background spectra that are recorded by...

Discrimination of Recoil Backgrounds in Scintillating Calorimeters (2009)

Lang, R. F., Angloher, G., Bauer, M., Bavykina, I., Bento, A., Brown, A., ...

The alpha decay of $\n{{}^{210}Po}$ is a dangerous background to rare event searches. Here, we describe observations related to this alpha decay in the Cryogenic Rare Event Search with...

Commissioning Run of the CRESST-II Dark Matter Search (2008)

Angloher, G., Bauer, M., Bavykina, I., Bento, A., Brown, A., Bucci, C., ...

The CRESST cryogenic direct dark matter search at Gran Sasso, searching for WIMPs via nuclear recoil, has been upgraded to CRESST-II by several changes and improvements.We present the results of a...

Investigation of ZnWO4 crystals as scintillating absorbers for direct Dark Matter search experiments (2008)

Bavykina, I., Angloher, G., Hauff, D., Pantic, E., Petricca, F., Proebst, F., ...

A high light yield at low temperatures is one of the key criteria in the choice of scintillating target crystals for the CRESST-II Dark Matter search. We perform a feasibility study on ZnWO4 crystals...

Isotopic Scaling and the Symmetry Energy in Spectator Fragmentation (2007)

Le Fèvre, A., Auger, G., Begemann-Blaich, M. L., Bellaize, N., Bittiger, R., Bocage, F., ...

Isotopic effects in the fragmentation of excited target residues following collisions of $^{12}$C on $^{112,124}$Sn at incident energies of 300 and 600 MeV per nucleon were studied with the INDRA...

Interpretation of Light-Quenching Factor Measurements (2007)

Bavykina, I., Christ, P., Huff, P., Ninkovic, J., Proebst, F., Seidel, W., ...

We observe that the pattern of the quenching factors for scintillation light from various ions, recently studied in $CaWO_4$ in connection with dark matter detectors, can be understood as a...

Critical revision of the ZEPLIN-I sensitivity to WIMP interactions (2007)

Benoit, A., Chapellier, M., Chardin, G., Dumoulin, L., Eitel, K., Gascon, J., ...

The ZEPLIN collaboration has recently published its first result presenting a maximum sensitivity of $1.1 \times 10^{-6}$ picobarn for a WIMP mass of $\approx$ 60 GeV. The analysis is based on a...

Critical revision of the ZEPLIN-I sensitivity to WIMP interactions (2007)

Benoit, A., Chapellier, M., Chardin, G., Dumoulin, L., Eitel, K., Gascon, J., ...

The ZEPLIN collaboration has recently published its first result presenting a maximum sensitivity of $1.1 \times 10^{-6}$ picobarn for a WIMP mass of $\approx$ 60 GeV. The analysis is based on a...

Critical revision of the ZEPLIN-I sensitivity to WIMP interactions (2007)

Benoit, A., Chapellier, M., Chardin, G., Dumoulin, L., Eitel, K., Gascon, J., ...

The ZEPLIN collaboration has recently published its first result presenting a maximum sensitivity of $1.1 \times 10^{-6}$ picobarn for a WIMP mass of $\approx$ 60 GeV. The analysis is based on a...

Interpretation of Light-Quenching Factor Measurements (2007)

Bavykina, I., Christ, P., Huff, P., Ninkovic, J., Proebst, F., Seidel, W., ...

We observe that the pattern of the quenching factors for scintillation light from various ions, recently studied in $CaWO_4$ in connection with dark matter detectors, can be understood as a...

CRESST – status and future (2007)

Kraus, H., Angloher, G., Bauer, M., Bavykina, I., Bucci, C., Christ, P., ...

We present results on WIMP dark matter interaction, obtained using cryogenic phonon-scintillation detectors. The targets are CaWO4 scintillating crystals with phonon sensors, while scintillation is...

Fracture Processes Observed with A Cryogenic Detector (2006)

Astrom, J., Proebst, F., Stodolsky, L., Timonen, J., Bucci, C., ...

In the early stages of running of the CRESST dark matter search using sapphire detectors at very low temperature, an unexpectedly high rate of signal pulses appeared. Their origin was finally traced...

Fracture Processes Observed with A Cryogenic Detector (2006)

Astrom, J., Proebst, F., Stodolsky, L., Timonen, J., Bucci, C., ...

In the early stages of running of the CRESST dark matter search using sapphire detectors at very low temperature, an unexpectedly high rate of signal pulses appeared. Their origin was finally traced...

Critical revision of the ZEPLIN-I sensitivity to WIMP interactions (2006)

Benoit, A., Chapellier, M., Chardin, G., Dumoulin, L., Eitel, K., Gascon, J., ...

The ZEPLIN collaboration has recently published its first result presenting a maximum sensitivity of $1.1 \times 10^{-6}$ picobarn for a WIMP mass of $\approx$ 60 GeV. The analysis is based on a...

Fracture processes studied in CRESST (2006)

Angström, J., Pröbst, F., Stodolsky, L., Timonen, J., Bucci, C., ...

In the early stages of running of the CRESST dark matter search with sapphire crystals as detectors, an unexpectedly high rate of signal pulses appeared. Their origin was finally traced to fracture...

Fracture Processes Oberved with A Cryogenic Detector (2006)

Astrom, J., Stodolsky, F. Proebst. L., Timonen, J., Bucci, C., Cooper, S., Cozzini, C., ...

In the early stages of running of the CRESST dark matter search using sapphire detectors at very low temperature, an unexpectedly high rate of signal pulses appeared. Their origin was finally traced...

Critical revision of the ZEPLIN-I sensitivity to WIMP interactions (2006)

Benoit, A., Chapellier, M., Chardin, G., Dumoulin, L., Eitel, K., Gascon, J., ...

The ZEPLIN collaboration has recently published its first result presenting a maximum sensitivity of $1.1 \times 10^{-6}$ picobarn for a WIMP mass of $\approx$ 60 GeV. The analysis is based on a...

EURECA - the European future of cryogenic dark matter searches. (2006)

Kraus, H., Bauer, M., Benoit, A., Blümer, J., Broniatowski, A., Camus, P., ...

9th Internat.Conf.on Topics in Astroparticle and Underground Physics, Zaragoza, E, September 10-14, 2005

Critical revision of the ZEPLIN-I sensitivity to WIMP interactions (2005)

Benoît, A, Chapellier, M, Chardin, G, Dumoulin, L, Eitel, K, Gascon, J, ...

The ZEPLIN collaboration has recently published its first result presenting a maximum sensitivity of $1.1 \times 10^{-6}$ picobarn for a WIMP mass of $\approx$ 60 GeV. The analysis is based on a...

Critical revision of the ZEPLIN-I sensitivity to WIMP interactions (2005)

Benoit, A., Chapellier, M., Chardin, G., Dumoulin, L., Eitel, K., Gascon, J., ...

The ZEPLIN collaboration has recently published its first result presenting a maximum sensitivity of $1.1 \times 10^{-6}$ picobarn for a WIMP mass of $\approx$ 60 GeV. The analysis is based on a...

Fracture Processes Observed with A Cryogenic Detector (2005)

Astrom, J., Proebst, F., Stodolsky, L., Timonen, J., Bucci, C., ...

In the early stages of running of the CRESST dark matter search using sapphire detectors at very low temperature, an unexpectedly high rate of signal pulses appeared. Their origin was finally traced...

Isotopic Scaling and the Symmetry Energy in Spectator Fragmentation (2005)

Le Fèvre, A., Auger, G., Begemann-Blaich, M. L., Bellaize, N., Bittiger, R., Bocage, F., ...

Isotopic effects in the fragmentation of excited target residues following collisions of $^{12}$C on $^{112,124}$Sn at incident energies of 300 and 600 MeV per nucleon were studied with the INDRA...

Isotopic Scaling and the Symmetry Energy in Spectator Fragmentation (2005)

Le Fèvre, A., Auger, G., Begemann-Blaich, M. L., Bellaize, N., Bittiger, R., Bocage, F., ...

Isotopic effects in the fragmentation of excited target residues following collisions of $^{12}$C on $^{112,124}$Sn at incident energies of 300 and 600 MeV per nucleon were studied with the INDRA...

Limits on WIMP dark matter using scintillating CaWO4 cryogenic detectors with active background suppression (2005)

Angloher,G., Bucci,C., Christ,P., Cozzini,C., Von Feilitzsch,F., Hauff,D., ...

We present first significant limits on WIMP dark matter by the phonon-light technique, where combined phonon and light signals from a scintillating cryogenic detector are used. Data from early 2004...

The CRESST Dark Matter Search (2005)

Majorovits,B., Angloher,G., Bucci,C., Christ,P., Cozzini,C., Von Feilitzsch,F., ...

We present first competitive results on WIMP dark matter using the phonon-light-detection technique. A particularly strong limit for WIMPs with coherent scattering results from selecting a region of...

Radiation sensor system for the undulator U27 using optical fiber (2005)

Seidel, W., Kuhnhenn, J., Weinand, U., Schamlott, A.

Am Forschungszentrum Rossendorf wurde am Undulator des ELBE Beschleunigers ein faseroptisches Sensorsystem zur Erfassung der Dosis aufgebaut. Dieses System erlaubt eine sehr schnelle Messung der...

Limits on WIMP dark matter using scintillating CaWO4 cryogenic detectors with active background suppression (2005)

Angloher, G., Bucci, C., Christ, P., Cozzini, C., Von Feilitzsch, F., Hauff, D., ...

We present first significant limits on WIMP dark matter by the phonon-light technique, where combined phonon and light signals from a scintillating cryogenic detector are used. Data from early 2004...

The CRESST Dark Matter Search (2005)

Majorovits, B., Angloher, G., Bucci, C., Christ, P., Cozzini, C., Von Feilitzsch, F., ...

We present first competitive results on WIMP dark matter using the phonon-light-detection technique. A particularly strong limit for WIMPs with coherent scattering results from selecting a region of...

The CRESST Dark Matter Search (2004)

Majorovits, B., Angloher, G., Bucci, C., Christ, P., Cozzini, C., Von Feilitzsch, F., ...

We present first competitive results on WIMP dark matter using the phonon-light-detection technique. A particularly strong limit for WIMPs with coherent scattering results from selecting a region of...

Isotopic Scaling and the Symmetry Energy in Spectator Fragmentation (2004)

INDRA, The, Auger, G., Begemann-Blaich, M. L., Bellaize, N., Bittiger, R., ...

Isotopic effects in the fragmentation of excited target residues following collisions of $^{12}$C on $^{112,124}$Sn at incident energies of 300 and 600 MeV per nucleon were studied with the INDRA...

Detection of the Natural Alpha Decay of Tungsten (2004)

Cozzini, C., Angloher, G., Bucci, C., Von Feilitzsch, F., Hauff, D., Henry, S., ...

The natural alpha decay of 180W has been unambiguously detected for the first time. The alpha peak is found in a (gamma,beta and neutron)-free background spectrum. This has been achieved by the...

Limits on WIMP dark matter using scintillating CaWO4 cryogenic detectors with active background suppression (2004)

Angloher, G., Bucci, C., Christ, P., Cozzini, C., Von Feilitzsch, F., Hauff, D., ...

We present first significant limits on WIMP dark matter by the phonon-light technique, where combined phonon and light signals from a scintillating cryogenic detector are used. Data from early 2004...

Detection of the Natural Alpha Decay of Tungsten (2004)

Cozzini,C., Angloher,G., Bucci,C., Von Feilitzsch,F., Hauff,D., Henry,S., ...

The natural alpha decay of 180W has been unambiguously detected for the first time. The alpha peak is found in a (gamma,beta and neutron)-free background spectrum. This has been achieved by the...

High detection sensitivity achieved with cryogenic detectors in combination with matrix-assisted laser desorption / ionisation time-of-flight mass spectrometry (MALDI-TOF MS) (2004)

Christ, P., Rutzinger, S., Koy, C., Seidel, W., Uchaikin, S., Glocker, M. O., ...

Cryogenic detectors directly measure the impact energy of any impinging particle independent of its velocity. Thus a very high, mass-independent, detection efficiency is expected from their...

Detection of the Natural Alpha Decay of Tungsten (2004)

Cozzini, C., Angloher, G., Bucci, C., Von Feilitzsch, F., Hauff, D., Henry, S., ...

The natural alpha decay of 180W has been unambiguously detected for the first time. The alpha peak is found in a (gamma,beta and neutron)-free background spectrum. This has been achieved by the...

A Textured Silicon Calorimetric Light Detector (2003)

Frank, T., Angloher, G., Bruckmayer, M., Cozzini, C., Hauff, D., ...

We apply the standard photovoltaic technique of texturing to reduce the reflectivity of silicon cryogenic calorimetric light detectors. In the case of photons with random incidence angles, absorption...

A Textured Silicon Calorimetric Light Detector (2003)

Frank, T., Angloher, G., Bruckmayer, M., Cozzini, C., Hauff, D., ...

We apply the standard photovoltaic technique of texturing to reduce the reflectivity of silicon cryogenic calorimetric light detectors. In the case of photons with random incidence angles, absorption...

Prospective analysis of the impact of HLA-DR and -DQ on joint destruction in recent-onset rheumatoid arthritis (2003)

Wagner, U., Kaltenhäuser, S., Pierer, M., Seidel, W., Tröltzsch, M., Häntzschel, H., ...

Objective. To evaluate the differential impact of HLA-DR and -DQ on the progression of erosive disease in the clinical course of early rheumatoid arthritis (RA). Methods. HLA genotyping for HLA-DR...

Prospective analysis of the impact of HLA-DR and -DQ on joint destruction in recent-onset rheumatoid arthritis (2003)

Wagner, U., Kaltenhäuser, S., Pierer, M., Seidel, W., Tröltzsch, M., Häntzschel, H., ...

Objective. To evaluate the differential impact of HLA‐DR and ‐DQ on the progression of erosive disease in the clinical course of early rheumatoid arthritis (RA). Methods. HLA...

Prospective analysis of the impact of HLA-DR and -DQ on joint destruction in recent-onset rheumatoid arthritis (2003)

Wagner, U., Kaltenhäuser, S., Pierer, M., Seidel, W., Tröltzsch, M., Häntzschel, H., ...

Objective. To evaluate the differential impact of HLA-DR and -DQ on the progression of erosive disease in the clinical course of early rheumatoid arthritis (RA). Methods. HLA genotyping for HLA-DR...

Development of 300 g scintillating calorimeters (2002)

Frank,T., Angloher,G., Bruckmayer,M., Cozzini,C., Di Stefano,P., Hauff,D., ...

The sensitivity of WIMP detection can be improved by an ability to efficiently discriminate the gamma and beta backgrounds from the nuclear recoil signals. The CRESST phase II detectors will achieve...

Limits on WIMP Dark Matter using Sapphire Cryogenic Detectors (2002)

Angloher,G., Bruckmayer,M., Bucci,C., Bühler,M., Cooper,S., Cozzini,C., ...

Data taken by CRESST with a cryogenic detector system based on 262 g sapphire crystals has been used to place limits on WIMP dark matter in the Galactic Halo. The experiment was especially sensitive...

Cross-sectional TEM study of the microstructure of superconducting X-ray detectors based on thin W-Al layers (2002)

Sáfrán,G., Loidl,M., Meier,O., Seidel,W., Pröbst,F.

The relation between structural and morphological properties and the performance of X-ray detectors have been studied by means of cross-sectional transmission electron microscopy (XTEM)and low...

Results of CRESST Phase I (2002)

Pröbst,F., Angloher,G., Bruckmayer,M., Bucci,C., Cooper,S., Di Stefano,P., ...

Results of the CRESST experiment at Gran Sasso using 262 g sapphire calorimeters with tungsten phase transition thermometers are presented. Calibration and analysis methods are described. Data taken...

Development of 300 g scintillating calorimeters (2002)

Frank, T., Angloher, G., Bruckmayer, M., Cozzini, C., Di Stefano, P., Hauff, D., ...

The sensitivity of WIMP detection can be improved by an ability to efficiently discriminate the gamma and beta backgrounds from the nuclear recoil signals. The CRESST phase II detectors will achieve...

Limits on WIMP Dark Matter using Sapphire Cryogenic Detectors (2002)

Angloher, G., Bruckmayer, M., Bucci, C., Bühler, M., Cooper, S., Cozzini, C., ...

Data taken by CRESST with a cryogenic detector system based on 262 g sapphire crystals has been used to place limits on WIMP dark matter in the Galactic Halo. The experiment was especially sensitive...

Cross-sectional TEM study of the microstructure of superconducting X-ray detectors based on thin W-Al layers (2002)

Sáfrán, G., Loidl, M., Meier, O., Seidel, W., Pröbst, F.

The relation between structural and morphological properties and the performance of X-ray detectors have been studied by means of cross-sectional transmission electron microscopy (XTEM)and low...

Results of CRESST Phase I (2002)

Pröbst, F., Angloher, G., Bruckmayer, M., Bucci, C., Cooper, S., Di Stefano, P., ...

Results of the CRESST experiment at Gran Sasso using 262 g sapphire calorimeters with tungsten phase transition thermometers are presented. Calibration and analysis methods are described. Data taken...

Results and plans of the CRESST dark matter search (2001)

Altmann, M., Angloher, G., Bruckmayer, M., Bucci, C., Cooper, S., Cozzini, C., ...

Data taken by CRESST in 2000 with a cryogenic detector system based on 262 g sapphire crystals is used to place limits on WIMP dark matter in the Galactic Halo. The detector is especially sensitive...

The CRESST Experiment: Recent Results and Prospects (2000)

Di Stefano, P., Bruckmayer, M., Bucci, C., Cooper, S., Cozzini, C., Von Feilitzsch, F., ...

The CRESST experiment seeks hypothetical WIMP particles that could account for the bulk of dark matter in the Universe. The detectors are cryogenic calorimeters in which WIMPs would scatter...

Discrimination between Nuclear Recoils and Electron Recoils by Simultaneous Detection of Phonons and Scintillation Light (1999)

Meunier, P., Bravin, M., Bruckmayer, M., Giordano, S., Loidl, M., Meier, O., ...

We have developed a detector, consisting of a cryogenic calorimeter with a scintillating crystal as absorber, and a second calorimeter for the detection of the scintillation light, both operated at...

Universality of Spectator Fragmentation at Relativistic Bombarding Energies (1996)

Schuettauf, A., Kunze, W. D., Woerner, A., Begemann-Blaich, M., Blaich, Th., Bowman, D. R., ...

Multi-fragment decays of 129Xe, 197Au, and 238U projectiles in collisions with Be, C, Al, Cu, In, Au, and U targets at energies between E/A = 400 MeV and 1000 MeV have been studied with the ALADIN...

Analogue detection device for scattering experiments and velocity analysis (1977)

Seidel, W., Streich, M.

A detecting system for molecular beam experiments is described which may be used for the detection of very small particle fluxes as well as for beam calibration (higher flux). The system is tested...

Analogue detection device for scattering experiments and velocity analysis (1977)

Seidel, W., Streich, M.

A detecting system for molecular beam experiments is described which may be used for the detection of very small particle fluxes as well as for beam calibration (higher flux). The system is tested...

Analogue detection device for scattering experiments and velocity analysis (1977)

Seidel, W., Streich, M.

A detecting system for molecular beam experiments is described which may be used for the detection of very small particle fluxes as well as for beam calibration (higher flux). The system is tested...

CaWO4 crystals as scintillators for cryogenic dark matter search

Ninkovic,J., Angloher,G., Bucci,C., Cozzini,C., Frank,T., Hauff,D., ...

Although it is well known that CaWO4 is a scintillator it is not often used, mainly because it has a slow light response. However, a high Z and a good light output make this crystal a candidate for...

Development of a superconducting-phase-transition thermometer (SPT) for the application in a time-of-flight mass spectrometer (TOF-MS) for heavy-mass molecules

Rutzinger,S., Christ,P., Pröbst,F., Seidel,W., Uchaikin,S.

We report on a newly developed detector based on a Superconducting-Phase-Transition Thermometer (SPT) which is used in a TOF-MS for heavy molecules. It exhibits a sensitive area of 3.0 x 3.0 mm and a...

CRESST-II: dark matter search with scintillating absorbers

Angloher,G., Bucci,C., Cozzini,C., Von Feilitzsch,F., Frank,T., Hauff,D., ...

In the CRESST-II experiment, scintillating CaWO4 crystals are used as absorbers for direct WIMP (weakly interacting massive particles) detection. Nuclear recoils can be discriminated against electron...

A Textured Silicon Calorimetric Light Detector

Frank,T., Angloher,G., Bruckmayer,M., Cozzini,C., Hauff,D., ...

We apply the standard photovoltaic technique of texturing to reduce the reflectivity of silicon cryogenic calorimetric light detectors. In the case of photons with random incidence angles, absorption...

Light detector development for CRESST-II

Petricca,F., Angloher,G., Cozzini,C., Frank,T., Hauff,D., Ninkovic,J., ...

CRESST-II detector modules rely on the ability to actively discriminate electron recoils from nuclear recoils via simultaneous measurement of phonons and scintillation light. The scintillation light...

CRESST-II: dark matter search with scintillating absorbers

Angloher,G., Bucci D,C., Cozzini,C., Von Feilitzsch,F., Frank,T., Hauff,D., ...

In the CRESST-II experiment, scintillating CaWO4 crystals are used as absorbers for direct WIMP (weakly inter-acting massive particles) detection. Nuclear recoils can be discriminated against...

High detection sensitivity achieved with cryogenic detectors in combination with matrix-assisted laser desorption / ionisation time-of-flight mass spectrometry (MALDI-TOF MS)

Christ,P., Rutzinger,S., Koy,C., Seidel,W., Uchaikin,S., Glocker,M. O., ...

Cryogenic detectors directly measure the impact energy of any impinging particle independent of its velocity. Thus a very high, mass-independent, detection efficiency is expected from their...

CaWO4 crystals as scintillators for cryogenic dark matter search

Ninkovic, J., Angloher, G., Bucci, C., Cozzini, C., Frank, T., Hauff, D., ...

Although it is well known that CaWO4 is a scintillator it is not often used, mainly because it has a slow light response. However, a high Z and a good light output make this crystal a candidate for...

Development of a superconducting-phase-transition thermometer (SPT) for the application in a time-of-flight mass spectrometer (TOF-MS) for heavy-mass molecules

Rutzinger, S., Christ, P., Pröbst, F., Seidel, W., Uchaikin, S.

We report on a newly developed detector based on a Superconducting-Phase-Transition Thermometer (SPT) which is used in a TOF-MS for heavy molecules. It exhibits a sensitive area of 3.0 x 3.0 mm and a...

CRESST-II: dark matter search with scintillating absorbers

Angloher, G., Bucci, C., Cozzini, C., Von Feilitzsch, F., Frank, T., Hauff, D., ...

In the CRESST-II experiment, scintillating CaWO4 crystals are used as absorbers for direct WIMP (weakly interacting massive particles) detection. Nuclear recoils can be discriminated against electron...

Light detector development for CRESST-II

Petricca, F., Angloher, G., Cozzini, C., Frank, T., Hauff, D., Ninkovic, J., ...

CRESST-II detector modules rely on the ability to actively discriminate electron recoils from nuclear recoils via simultaneous measurement of phonons and scintillation light. The scintillation light...

CRESST-II: dark matter search with scintillating absorbers

Angloher, G., Bucci D, C., Cozzini, C., Von Feilitzsch, F., Frank, T., Hauff, D., ...

In the CRESST-II experiment, scintillating CaWO4 crystals are used as absorbers for direct WIMP (weakly inter-acting massive particles) detection. Nuclear recoils can be discriminated against...

CRESST: First results with the phonon-light technique

Petricca, F., Angloher, G., Bucci, C., Christ, P., Cozzini, C., Von Feilitzsch, F., ...

We present first significant limits on WIMP dark matter by the phonon-light technique, where combined phonon and light signals from a scintillating cryogenic detector are used to suppress the...

Polymyalgia rheumatica and rheumatoid arthritis of the elderly: a clinical, laboratory, and scintigraphic comparison.

Häntzschel, H, Bird, H A, Seidel, W, Krüger, W, Neumann, G, Schneider, G, ...

Clinical, laboratory, and scintigraphic features of 16 patients with polymyalgia rheumatica and 23 patients matched for age presenting with classical or definite rheumatoid arthritis (American...

The CRESST Dark Matter Search

Bavykina, I., Bento, A., Hauff, D., Huff, P., Lang, R., Majorovits, B., ...

CRESST II is a WIMP search experiment using cryogenic detectors to detect heat and scintillation signals in CaWO$_4$ crystals simultaneously. Competitive limits on the coherent WIMP-nucleon...

The CRESST Dark Matter Search

Seidel, W, Angloher, G, Bauer, M, Bavykina, I, Bento, A, Brown, A, ...

CRESST is a WIMP dark matter search using scintillating CaWO4 cryogenic detectors with active background suppression. First results obtained in the commissioning run are presented.